The 2080 is simple to use and provides the following tests :
Insulation Testers
3 high value resistors (1 MOhm, 9.9 MOhm and 99 MOhm) for testing resistance measurementsLED indication of test voltage at 100V, 250V, 500V and 1000V3 low value resistors (0.5 Ohms, 2 Ohms and 10 Ohms) for testing of continuity function (as applicable)AC Line voltage output for test voltage measurement
RCD Testers
Dedicated 13A socket provides instant testing of RCD testersfixed test points of 10mA @ 150ms, 30mA @ 150ms and 150mA @ 30msLED indicators of test status
Loop Testers
Provides Loop and Loop + 1 Ohm test function for quick verification of Loop testers
Wiring Check
When connected to mains, the 2080 will indicate correct or incorrect wiring through 3 LEDs for instant feedback
Included with the 2080 is a calibration check sheet for your instrument.
Insulation Testers 10GΩ
RCD Current Measurement to 3A
loop options
Wiring Check
Continuity Ranges : 0.5Ohms • 2 Ohms • 10Ohms
Continuity Accuracy : 1% ± 20mOhms
Continuity Current (Max.) : 300mA
Insulation Ranges : 1MOhms • 9.9MOhm • 99MOhms
Insulation Accuracy : 1%
Insulation : Maximum Voltage : 1.2kV
RCD Ranges : 10mA (Nominal) @ 150ms
: 30mA (Nominal) @ 150ms
: 150mA (Nominal) @ 30ms
LOOP Resistance Ranges : Supply Loop
: Supply Loop + 1 Ohm
LOOP Resistance Accuracy : 5%
GENERAL
Power Supply : 230V LINE INPUT
Dimensions : 275 X 230 X 83mm
Weight : 2.5kg
Accessories : MANUAL, TEST SHEET