Battery Extra Load Units BXL Series are designed as an additional load to be used with BLU series if required discharge current or power exceeds the capacity of available BLU device(s). BXL Series devices are based on a state-of-theart technology - the most advanced power electronics solutions are used as well as 6-8 fans which are integrated into the device. BXL Series are powerful devices which provide high discharge currents (up to 310 A DC) applicable up to 500 V DC battery systems. System of a BLU and BXL enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards (IEEE 450-2010 / 11882005 / 1106-2015, IEC 60896-11/22 and other relevant standards).
A BLU device (in a BLU-BXL system) ensures control of the discharge process. BXL simulates constant resistance load during the discharge test – its load parameter (resistance) can be set prior the discharge test. BXL provides flexibility in selecting its load capacities – several resistances can be set for most of nominal battery voltages. Overview of the maximum currents for various battery voltage ranges with the minimum achievable cell voltage of 1,75 V is presented in the_Table_1.
Used in a system with BLU device to increase load capacity
Lightweight – starting from 12,5 kg (28 lbs.)
Powerful – discharge power of up to 35 kW
Voltage measurement range: up to 500 V DC
Discharge current – up to 310 A DC
Measurement resolution – current 1 A, voltage 1 V
Discharge process controlled by BLU device
Connects to battery terminals and parallel to BLU device
Mains Power Supply
Connection according to IEC/EN60320-1; C320
Voltage: 90 V – 264 V AC, 50 / 60 Hz, single-phase
Input power: 200 VA
Fuse 2 A / 250 V, type F
Dimensions and Weights
Model Dimensions Weight
BXL-A 560 x 221 x 355 mm (22 x 8.7 x 14 in) 12,5 kg 28 lbs.
BXL-T 560 x 221 x 355 mm (22 x 8.7 x 14 in) 12,5 kg 28 lbs.
BXL-V 730 x 221 x 355 mm (28.7 x 8.7 x 14 in) 16 kg 35 lbs.
Maximum discharge current & power
Model Current Power
BXL-A 250 A 25,4 kW
BXL-T 310 A 17,5 kW
BXL-V 190 A 35,0 kW
Measurement
Internal voltage measurement
Model Range Resolution
BXL-A 0 – 300 V DC 1 V
BXL-T 0 – 75 V DC 1 V
BXL-V 0 – 500 V DC 1 V
Typical accuracy: ± 0,5% of reading ± 1 V
Internal current measurement
Model Range Resolution
BXL-A 0 – 300 A DC 1 A
BXL-T 0 – 450 A DC 1 A
BXL-V 0 – 250 A DC 1 A
Typical accuracy: ± 0,5% of reading ± 1 A
Warranty: 3 years
Display
LCD screen 16 characters by 2 lines,
LCD display with backlight, visible in bright sunlight
Environment conditions
Operating temperature: -10 °C to +45 °C / 14 °F to +113 °F
Storage & Transportation temperature: -40 °C to +70 °C / -40 °F to +158 °F
Maximum relative humidity 95% for temperatures up to 31 °C (88 °F), decreasing linearly to 40% relative humidity at 55 °C (131 °F)
Pollution degree: 2
Applicable Standards (for BLU-BXL system)
IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11, IEC 60896-22 and other relevant standards
Installation/overvoltage: category II
Pollution: degree 2
Safety - Low Voltage Directive: Directive 2014/35/EU (CE conform) Applicable standards, for a class I instrument, pollution degree 2, Installation category II: IEC EN 61010-1
Electromagnetic Compatibility: - Directive 2014/30/EU (CE conform) _Applicable standard: EN 61326-1
CAN/CSA-C22.2 No. 61010-1