Three-Phase Transformer Turns Ratio Tester

  • Product No:TRT03 Series
  • Manufacturer:IBEKO Power AB (DV-Power)
  • TRT03 is a three-phase, fully automatic test set specially designed for turns ratio, phase shift, and excitation current measurements of power, distribution and instrument transformers. TRT03 determines the transformer turns ratio by applying voltages across high voltage windings, accurately measuring voltages across the unloaded transformer windings, and then displaying the ratio of these voltages.

  • TRT03 is based on a state of the art technology, using the most advanced technique available today. The test set can be used to test singlephase and three-phase transformers, both with and without taps in accordance with the requirements of the IEC 60076-1 standard.

  • For a three-phase measurement, the test set is connected to all the three phases of a transformer to be tested. If specific vector diagrams are selected for different types of transformers, the TRT03 will run a specific test for each transformer type (i.e., single phase,  Delta to wye/star, Wye/Star to delta, Delta to delta, Wye/Star to wye/star, Delta to zig-zag, etc.) without a need to switch the test hookup cables. Following the test, it displays a turns ratio, phase shift, and excitation current.

  • TRT03 lets users enter a transformer’s nameplate voltages for the turns ratio deviation calculation. This feature eliminates any error otherwise caused by an operator’s manual calculation. The TRT03 also compares the test result with the nameplate ratio and prints out the % of error for each test.

  • Operating conditions messages or error messages identify incorrect test conditions, abnormal operating condition or transformer problems. TRT03 has a very high ability to cancel electrostatic and electromagnetic interference in HV electric fields. It is achieved by a very efficient filtration. The filtration is made utilizing the proprietary hardware and software design solutions.


Mains Power Supply

  • Connection: according to IEC/EN60320-1; UL498, CSA 22.2 

  • Mains supply: 90 –  264 V AC, 50/60 Hz  or 110 – 350 V DC 

  • Input power: 200 VA 

  • Fuse: 2 A / 250 V, type F, not user replaceable

Output Data

  • Instrument / Test voltages

    TRT03A     8, 40, 100 V AC

    TRT03B     10, 40, 100 V AC

    TRT03C     8, 40, 80 V AC

Measurement

  • Turns ratio measuring range: 0,8 – 50 000 

  • Turns ratio resolution: 5 digits

  • Typical turns ratio accuracy:

    @80 or 100 V AC                  @40 V AC                                
    0,8 – 999: ±0,05%                 0,8 – 999: ±0,05%
    1 000 – 3 999: ±0,05%          1 000 – 3 999: ±0,1%
    4 000 – 14 999: ±0,1%          4 000 – 14 999: ±0,2%
    15 000 – 19 999: ±0,2%        15 000 – 20 000: ±0,3%
    20 000 – 50 000:±0,25%

    @8 or 10 V AC 
    0,8 – 999: ±0,05% 
    1 000 – 3 999: ±0,1% 
    4 000 – 15 000: ±0,2%

  • Excitation current range: 0 – 2 A 

  • Excitation current resolution:     

    0,0000 – 9,9999 mA    0,1 μA            

    10,000 – 99,999 mA    1 μA               

    100,00 – 999,99 mA    10 μA             

    1,0000 – 2,0000 A       100 μA      

  • Typical excitation current accuracy:  ±(0,25% rdg + 500 μA)

  • Phase angle range: 0 – 360º 

  • Phase angle resolution: 0,01º 

  • Typical phase angle accuracy: ±0,05º

Display

  • LCD screen 20 characters by 4 lines; 

  • LCD display with backlight, visible in bright sunlight

Interface

  • USB (standard) 

  • RS232 (optional)

Data Storage 

  • TRT03 can store up to 10 000 test results

Environmental Conditions

  • Operating temperature: -10 ºC – +55 ºC / 14 ºF – +131 ºF 

  • Storage & transportation:  -40 ºC – +70ºC / -40 ºF – +158 ºF 

  • Humidity: 5% – 95% relative humidity, non condensing 

Dimensions and Weight

  • Dimensions (W x H x D):  480 x 190 x 385 mm / 18.9 x 7.48 x 15.16 in 

  • Weight: 8 kg / 17.6 lbs

Warranty

  • 3 years

Printer (optional)

  • Built-in thermal printer 

  • Paper width 112 mm / 4.4 in 

  • Printer operating temperature:  0 ºC – +50 ºC / 32 ºF – +122 ºF 

  • Printer density is guaranteed in this range: 5 ºC – +40 ºC / 41 ºF – +104 ºF                            

                                                                        20 – 85% relative humidity, non condensing